Winter heating method for factory floors, 6000 square meters heating plan

With the continuous development of industrial level, the form and scale of factories have also developed significantly, and the original factory heating equipment has also exposed its disadvantages.

Winter heating method for factory floors, 6000 square meters heating plan

First of all, the factory building scale is large , It is difficult to arrange heating methods and it is difficult to meet the design temperature requirements. Secondly, the height is generally higher and the space is larger. Compared with ordinary residential buildings, the heating effect is very difficult to guarantee. The heating equipment in ordinary factories is severely hot and cold. , Due to the severe wind in the factory, the dust and dust in the factory are flying, and the hygiene conditions are poor, which affects the production process and directly affects the quality of the product. In the space of tall factories, the choice of heating methods in winter is of great importance.

There are many heating equipments in the market, including coal-fired boilers, industrial heating machines, air energy heat pumps, etc.

Winter heating method for factory floors, 6000 square meters heating plan

To ensure winter production Proceed smoothly, to ensure the quality and production progress of the product, especially for large cars with strong production capabilities. Winter heating is of great importance. In recent years, China has implemented the \”coal-to-electricity conversion\”, and many companies are looking for suitable alternatives to coal boilers. , which heating equipment is more efficient and more advantageous? The following points are very important

1. The stability of heating equipment

The traditional resistive hot water boiler directly supplies power to the resistor rod, which is prone to overcurrent impact and voltage fluctuations. There is a problem with stability. The air source heat pump is a energy device that uses high energy to make the heat flow from the low heat source to the high heat source. The core adopts the \”reverse Kano\” circulation principle, such as the gold-sun air source heat pump unit, which uses an imported compressor, and is equipped with expansion valves, condensers, The three major components of the evaporator provide reliable guarantees for the stable operation of the air source heat pump with the support of a variety of technologies including full DC frequency and spray pressure.

2. Safety of heating equipment

The air source heat pump unit can achieve water and electricity separation, and have higher safety. Ordinary electric heating boilers use resistor rods to directly heat the water, and there is no real water-electric separation, which poses a great safety hazard.

3, heating equipment energy efficiency

The air source heat pump unit has a high energy efficiency ratio, which is more than 30% compared to ordinary boiler energy.

Winter heating method for factory floors, 6000 square meters heating plan

4. Convenient installation of heating equipment

The air source heat pump unit provides customized services according to different heating sites, covering small-power garage and large-side heating. The Jinhuang air source heat pump unit can provide customized air energy Heating equipment.

Therefore, the editor recommends that large vehicles use air source heat pump unit to heat the air. The choice of air energy equipment power in a vehicle room must be based on the building conditions and test data of the vehicle, generally in Based on the demand-based approach, some balance is left, which not only meets the heating demand in the car, but also achieves the effect of saving power.

Winter heating method for factory floors, 6000 square meters heating plan

Example, the heating solution for a 6000 square meter factory room, and what power of the air source heat pump unit is required for a 6000 square meter heating?

The simple algorithm is like this: each heating area can be 20 square meters, so for 6,000 square meters, use a total of 300 air source heat pump unit. If the temperature maintenance of the car is not done well, you can consider purchasing a higher power. Air source heat pump unit. Therefore, the selection of air source heat pump unit actually requires consideration of conditions such as building materials, windiness, local outdoor average temperature and altitude in winter.

Winter heating method for factory floors, 6000 square meters heating plan

The requirements for the heating design of the industrial factory are the heating load and the required heat source. If it is closely related to the construction and structure expertise, if you want to achieve the required temperature in heating and reduce the energy consumption cost, you must take corresponding energy management measures in the building structure:

1. Glass can be used in the factory wall. Cotton board with plastic board or similar materials for warm maintenance;

2. The factory can be equipped with doors to ensure less cold wind penetration to the greatest extent, and at the same time, it can also avoid the occurrence of wind through the hall; it can be set on both sides of the door The electric curtain blocks the infusion of cold wind when the door opens;

3. The factory has as few exterior windows and roof skylights as possible.Use a double-layer sunroof to change the air. It can be fully opened in summer and completely closed in winter, with a tight seal, reducing the cooling air penetration generated from windows and walls.

Winter heating method for factory floors, 6000 square meters heating plan

Industrial factories and other tall buildings The heating design is based on the characteristics and parameters of the factory maintenance structure, and after conducting detailed load calculations and obtaining theoretical heat supply, select energy-saving and environmentally friendly heating methods to achieve the maximum heating effect. If the design parameters are large and the actual difference will cause negative load calculation deviation and insufficient negative load. Therefore, the maintenance structure of tall factories must be thorough in terms of doors, roofs, walls and windows, and meet the design requirements as much as possible to achieve the maximum extent energy consumption reduction

本站内容及图片来自网络,版权归原作者所有,内容仅供读者参考,不承担相关法律责任,如有侵犯请联系我们:609448834

Like (0)
华夏门网的头像华夏门网
Previous 2025年2月11日
Next 2025年2月11日

相关推荐

  • Video|Addressing Industrial Power County: Build a custom ecological door in 1 minute

    Video loading… When the company embraces intelligence, What chemical reaction will occur? On August 29, reporters came to the Shangpin Binse Intelligent House Intelligent Man…

    工业门 2025年2月16日
    50
  • How to choose factory industrial doors?

    How to choose industrial doors for factories? When building factories, how to choose industrial doors for workshops? Generally, the relative environmental area of ​​the workshop is…

    工业门 2024年12月12日
    30
  • 工业门的使用小技巧

    目前,工业门的应用非常广泛,然而很多企业在购买工业滑升门后,有很多地方都不知道如何去使用?下面就由我们华夏门网来为大家讲解一下工业门的使用技巧吧: 1、辅助装置:在酒店等地方需要杜绝自动门的夹人事件,可以选择安装防夹人红外感应器。 2、感应器的选择:在酒店、写字楼,可以选择高灵敏度的感应器;在人行道边上的银行、商店等经常有人路过的地方,选择窄区域的感应器。 …

    工业门 2023年10月23日
    300
  • Three dedicated line wheels of industrial door industry sliding doors

    Generally speaking, the industrial sliding door is stretched by wrapping the wire rope on the wire wheel. In order to achieve different ways of skating, we need to equip industrial…

    工业门 2025年1月30日
    50
  • 工业门的安全使用守则

    我们都非常重视工业门安全使用,一是它保护工厂财产安全,二是它一但出了故障,会威胁大家生命安全,下面华夏门网小编说说工业门使用安全提示。 1、请确保门体运行良好。只允许在安装了平衡弹簧、平衡良好的门体上安装开门机,否则可能造成开门机超载损坏;安装时您务必请专业安装人员进行检查和安装。 2、安装及布线必须依照建筑施工标准及电气标准进行,线径≧1.5mm2;电源线…

    工业门 2023年10月23日
    220

联系我们

400-800-8888

在线咨询: QQ交谈

邮件:[email protected]

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信