How should the clear width of a residential entrance door be calculated? The response to this controversial point comes

How should the clear width of a residential entrance door be calculated? The response to this controversial point comes

The pictures are all data pictures

How should the clear width of a residential entrance door be calculated? The response to this controversial point comes

Different people The net width of the entrance door has different understandings. Some people think it is the width of the door opening before the door is installed; some people think it is the width between the door frames after the door is installed (as shown on the left); others think it is the width of the human body after the door is opened (such as right picture).

□Dahe News·Dahe Client Reporter Cai Junyan

On October 29, Dahe News·Dahe Client published the article \”Does the net width of the entrance door include the thickness of the door frame and door panel?\” The title of \”Lawsuit between Owners and Developers\” was reported on the case of a resident in Zhongmou County suing the developer due to the clear width of the entrance door. This caused a stir and made some people in the construction circle feel uneasy, and also made some people in the construction industry feel uneasy. Some citizens are confused because the focus of the dispute between the two parties in the lawsuit is \”the net width of the entrance door should not be less than 0.9 meters.\” Does it refer to the width of the door opening before the door is installed, or the passing width after the door is installed, excluding the door frame and door panel? Many people are confused.

The reporter learned that this is due to the inconsistency between the national standards for door width in the \”Residential Design Code\” and the \”Building Design Fire Protection Code\”, and after the partial revision of the \”Building Design Fire Protection Code\”, the The meaning of \”clear width\” was unclear and the measurement method shown in the corresponding diagram was adjusted, which led to some complaints and even lawsuits. Industry insiders said that in response to this focus issue, they are actively reporting it to higher-level departments and working hard to resolve conflicts. In the next step, the net width of the entrance door will also have a tendency to be adjusted. In the 2019 draft for partial revision of the \”Code for Fire Protection Design of Buildings\”, it is planned to adjust the net width of the entrance door to 0.8 meters, and it is emphasized that this adjustment will not essentially affect the evacuation safety of personnel and the need for firefighters to carry equipment on their backs.

Confused about what is the standard for the clear width of an entrance door?

\”Entry doorHow should the net width be calculated? We also want to find out, otherwise we will feel unsure. \”Not long ago, Ms. Yang, the owner of a community in Zhongmou County, took the developer to court on the grounds that the width of the entrance door of her home was only 0.82 meters and did not meet national standards. It aroused a lot of attention, and everyone wanted to make a decision. Understood.

In this prosecution case, the owner believed that the clear width of the entrance door refers to the narrowest distance when the human body passes through the entrance door, that is, the clear width of the entrance door. However, the developer’s entrusted agent believes that based on the illustrations of the \”Building Design Fire Protection Code\”, it can be seen that the net width of the entrance door of a residential building is marked with the width of the door opening, which is 1.06 meters. When installing the door frame and The width of the entrance door behind the door panel is also 0.96 meters, which is also in compliance with relevant regulations… Both parties have different opinions.

In a construction company. Mr. Wang, who has worked for many years, told reporters that the reason for the dispute between the two parties is related to the mandatory provisions in the partially revised version of the \”Code for Fire Protection Design of Buildings\” that came into effect on October 1, 2018, which clearly states: \”Residential buildings The respective total clear widths of doors, safety exits, evacuation walkways and evacuation stairs should be calculated and determined, and the clear widths of doors and safety exits should be calculated and determined. The width should not be less than 0.9 meters, and the clear width of evacuation walkways, evacuation stairs and first-floor evacuation exterior doors should not be less than 1.1 meters…\” But what exactly does the clear width refer to? There is no clear and clear explanation in the specification, so that Disputes arise.

The problem is due to different requirements and the adjustment of the standard illustration.

In terms of the clear width of the entrance door, it is Why is there a dispute?

It is understood that on the one hand, the requirements for the width of the entrance door in the \”Residential Design Code\” and the \”Architectural Design Fire Protection Code\” are inconsistent, and on the other hand, it is also inconsistent with the \”Architectural Design Fire Protection Code\” The \”Residential Design Code\” implemented on August 1, 2012 is related to the adjustment of the illustrations before and after the partial revision of the Code. The minimum door opening width is 1 meter, but it does not involve issues such as the thickness of the door installed later.

The \”Building Design Fire Protection Code\” will be implemented on May 1, 2015 and October 1, 2018. The 2018 partially revised version of the \”Code for Fire Protection Design of Buildings\” that was implemented in 2018 has the same regulations on the clear width of the entrance door. However, the meaning of \”clear width\” is not clear. The description is not clear, but it has been supplemented in the corresponding illustrations of the \”Code for Fire Protection Design of Buildings\”

Industry insiders said that the illustrations of the \”Code for Fire Protection Design of Buildings\” have also been adjusted on September 1, 2014. , the illustrations of the \”Building Design Fire Protection Code\” implemented successively on June 1, 2015 are consistent with the illustrations of the entrance door. The width of the entrance door is the width of the door opening. However, the \”Building Design Fire Protection Code\” implemented on November 1, 2018 strengthens the width of the entrance door, clearly stating that the net width of the entrance door is not less than 0.9 meters, by adding the \”Schematic diagram of the net width of the evacuation door\” The method of enlarging the detailed drawing redefines the clear width calculation method, \”It can be seen from the enlarging detailed drawing that the clear width is the traffic width after the door is installed. \”Industry insiders said that due to the adjustment of the icon, the increase inProblems such as mismatch in design, construction and product standards have resulted in the clear width of some entrance doors being less than 0.9 meters.

Solution

Differential treatment for design and construction acceptance at different times

Industry insiders said that the partial revision of the \”Building Design Fire Protection Code\” and the adjustment of illustrations will bring Project design, construction, acceptance and other issues should be treated differently to prevent and control risks.

For projects that have not yet started, especially projects with a reserved door opening width of 1 meter

It is recommended that the design unit recalculate the width of the reserved opening, or remind the entrance door manufacturer in the future On the premise of ensuring quality, pay attention to the size of the door frame and ensure the net width of the entrance door; for the main construction phase of the project, if the reserved door opening width is 1.0 meters, it is recommended that the design institute review whether the reserved opening can be expanded, or adopt a method that meets the requirements Clear width requirements for entry doors.

For a completed project, if the measured width of the entrance door is less than 0.9 meters, it is recommended to conduct a detailed analysis of specific problems based on the measured width on site

The width error of the entrance door should be within 5% ( Net width is greater than 0.855 meters and less than 0.9 meters): According to Article 20 of the Ministry of Housing and Urban-Rural Development’s \”Regulations on Fire Protection Design Review and Acceptance of Construction Projects\”, the error does not exceed 5%, and it can be determined without affecting normal use functions and fire safety. To be qualified.

The net width of the entrance door is greater than or equal to 0.8 meters and less than 0.855 meters:

You can check the time when the \”Construction Engineering Fire Design Review Opinion\” was passed. If it was in 2018 Approval must be passed before November 1, 2019 (Illustration of \”Code for Fire Protection Design of Buildings\”, Atlas No. 18J811-1, date of approval), According to Article 40 of Order No. 51 of the Ministry of Housing and Urban-Rural Development, \”Before the implementation of the newly promulgated national fire protection technical standards for engineering construction, if the fire protection design of the construction project has been reviewed and qualified in accordance with the law, it shall be implemented according to the standards of the original review opinion\”, and it will be determined to be qualified; otherwise, it will be determined to be qualified. It is unqualified (note: 0.8 meters is based on the latest partial revision of the \”Building Design Fire Protection Code\”).

The net width of the entrance door is less than 0.8 meters:

It is judged as unqualified and the entrance door needs to be replaced.

Of course, the judgment of the above-mentioned qualified conclusion when it is less than 0.9 meters should be made by the construction unit to review the project design review time and the standards and specifications adopted.

Industry insiders said that as fire protection acceptance inspection becomes more and more strict, such conflicts accumulated in the early stage will gradually be resolved.

本站内容及图片来自网络,版权归原作者所有,内容仅供读者参考,不承担相关法律责任,如有侵犯请联系我们:609448834

(0)
华夏门网's avatar华夏门网
上一篇 2025年1月11日 10:28:58
下一篇 2025年1月11日 10:31:58

相关推荐

  • 金凱德榮獲2023-2024十大優選入戶門&智能門鎖品牌

    2024第八屆傢居品牌大會以“流量&質量”為主題,由傢居優品智庫主辦,中國建築材料流通協會、全聯傢具裝飾業商會、中國國際商會傢居建材產業委員會、北京傢居行業協會、廣東省定制傢居協會等5大權威協會指導,優居研究院、未來商業智庫戰略合作,樂居財經、新浪傢居、網易傢居、鳳凰網傢居、搜狐傢居、環球網傢居、中國網傢居、太平洋傢居、好傢生活網、傢居沒有圈、戴蓓T…

    入户门 2024年10月1日
    100
  • SIMBOR\’s new standard | Yufan series entry doors, luxurious taste and upgraded texture

    An entry door with both appearance and quality It can firmly maintain the warmth and emotion of home It also takes the beauty of your home to a new level New standard doors and win…

    入户门 2025年1月15日
    450
  • 今天才知道:入戶門不要對著這4處!如果你傢是這樣,趕緊改正

    老人經常說,回到傢之後,打開入住門,看到的景象可能會影響到傢裡的運勢和我們的心情。 聽起來是無稽之談,但是入戶門對應的物品和位置,還是有一些講究的。 我也是今天才知道,傢裡的入戶門不要對著這4處,如果你傢也是這樣,趕緊改正吧! 這可不是胡說,而是考慮到瞭傢裡整體的佈局,甚至還會關乎到我們的傢居安全。 下面就跟大傢分享一下,入戶門不能對著哪4處,看完你就明白瞭…

    入户门 2024年8月19日
    240
  • 入户门万万记得安装两扇门!别为了省那点小钱,弄得因小失大!

    入户门是保证家人及财产安全的第一道防护,因此在入户门的装修中,我们万万要注意起来,除了选择大品牌外,入户门的材料也务必要坚固才行,而我们也要记得在安装入户门的时候,安装两扇门,这样的话,有很多好处,不仅保证了安全,而且还有保温、隔音等好处,我们不要为了省钱就安装一扇门,那么可能因小失大! 一:入户门万万记得安装两扇门! 1、保温。除了不隔音以外,不锈钢防盗门…

    入户门 2023年10月26日
    620
  • What are your tips for purchasing entry doors?

    When choosing an entry door, first consider it from a safety perspective. After all, it is the first major barrier in the room. The door must be strong enough, and the door lock mu…

    入户门 2025年1月16日
    40

联系我们

400-800-8888

在线咨询: QQ交谈

邮件:[email protected]

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信