How should the clear width of a residential entrance door be calculated? The response to this controversial point comes

How should the clear width of a residential entrance door be calculated? The response to this controversial point comes

The pictures are all data pictures

How should the clear width of a residential entrance door be calculated? The response to this controversial point comes

Different people The net width of the entrance door has different understandings. Some people think it is the width of the door opening before the door is installed; some people think it is the width between the door frames after the door is installed (as shown on the left); others think it is the width of the human body after the door is opened (such as right picture).

□Dahe News·Dahe Client Reporter Cai Junyan

On October 29, Dahe News·Dahe Client published the article \”Does the net width of the entrance door include the thickness of the door frame and door panel?\” The title of \”Lawsuit between Owners and Developers\” was reported on the case of a resident in Zhongmou County suing the developer due to the clear width of the entrance door. This caused a stir and made some people in the construction circle feel uneasy, and also made some people in the construction industry feel uneasy. Some citizens are confused because the focus of the dispute between the two parties in the lawsuit is \”the net width of the entrance door should not be less than 0.9 meters.\” Does it refer to the width of the door opening before the door is installed, or the passing width after the door is installed, excluding the door frame and door panel? Many people are confused.

The reporter learned that this is due to the inconsistency between the national standards for door width in the \”Residential Design Code\” and the \”Building Design Fire Protection Code\”, and after the partial revision of the \”Building Design Fire Protection Code\”, the The meaning of \”clear width\” was unclear and the measurement method shown in the corresponding diagram was adjusted, which led to some complaints and even lawsuits. Industry insiders said that in response to this focus issue, they are actively reporting it to higher-level departments and working hard to resolve conflicts. In the next step, the net width of the entrance door will also have a tendency to be adjusted. In the 2019 draft for partial revision of the \”Code for Fire Protection Design of Buildings\”, it is planned to adjust the net width of the entrance door to 0.8 meters, and it is emphasized that this adjustment will not essentially affect the evacuation safety of personnel and the need for firefighters to carry equipment on their backs.

Confused about what is the standard for the clear width of an entrance door?

\”Entry doorHow should the net width be calculated? We also want to find out, otherwise we will feel unsure. \”Not long ago, Ms. Yang, the owner of a community in Zhongmou County, took the developer to court on the grounds that the width of the entrance door of her home was only 0.82 meters and did not meet national standards. It aroused a lot of attention, and everyone wanted to make a decision. Understood.

In this prosecution case, the owner believed that the clear width of the entrance door refers to the narrowest distance when the human body passes through the entrance door, that is, the clear width of the entrance door. However, the developer’s entrusted agent believes that based on the illustrations of the \”Building Design Fire Protection Code\”, it can be seen that the net width of the entrance door of a residential building is marked with the width of the door opening, which is 1.06 meters. When installing the door frame and The width of the entrance door behind the door panel is also 0.96 meters, which is also in compliance with relevant regulations… Both parties have different opinions.

In a construction company. Mr. Wang, who has worked for many years, told reporters that the reason for the dispute between the two parties is related to the mandatory provisions in the partially revised version of the \”Code for Fire Protection Design of Buildings\” that came into effect on October 1, 2018, which clearly states: \”Residential buildings The respective total clear widths of doors, safety exits, evacuation walkways and evacuation stairs should be calculated and determined, and the clear widths of doors and safety exits should be calculated and determined. The width should not be less than 0.9 meters, and the clear width of evacuation walkways, evacuation stairs and first-floor evacuation exterior doors should not be less than 1.1 meters…\” But what exactly does the clear width refer to? There is no clear and clear explanation in the specification, so that Disputes arise.

The problem is due to different requirements and the adjustment of the standard illustration.

In terms of the clear width of the entrance door, it is Why is there a dispute?

It is understood that on the one hand, the requirements for the width of the entrance door in the \”Residential Design Code\” and the \”Architectural Design Fire Protection Code\” are inconsistent, and on the other hand, it is also inconsistent with the \”Architectural Design Fire Protection Code\” The \”Residential Design Code\” implemented on August 1, 2012 is related to the adjustment of the illustrations before and after the partial revision of the Code. The minimum door opening width is 1 meter, but it does not involve issues such as the thickness of the door installed later.

The \”Building Design Fire Protection Code\” will be implemented on May 1, 2015 and October 1, 2018. The 2018 partially revised version of the \”Code for Fire Protection Design of Buildings\” that was implemented in 2018 has the same regulations on the clear width of the entrance door. However, the meaning of \”clear width\” is not clear. The description is not clear, but it has been supplemented in the corresponding illustrations of the \”Code for Fire Protection Design of Buildings\”

Industry insiders said that the illustrations of the \”Code for Fire Protection Design of Buildings\” have also been adjusted on September 1, 2014. , the illustrations of the \”Building Design Fire Protection Code\” implemented successively on June 1, 2015 are consistent with the illustrations of the entrance door. The width of the entrance door is the width of the door opening. However, the \”Building Design Fire Protection Code\” implemented on November 1, 2018 strengthens the width of the entrance door, clearly stating that the net width of the entrance door is not less than 0.9 meters, by adding the \”Schematic diagram of the net width of the evacuation door\” The method of enlarging the detailed drawing redefines the clear width calculation method, \”It can be seen from the enlarging detailed drawing that the clear width is the traffic width after the door is installed. \”Industry insiders said that due to the adjustment of the icon, the increase inProblems such as mismatch in design, construction and product standards have resulted in the clear width of some entrance doors being less than 0.9 meters.

Solution

Differential treatment for design and construction acceptance at different times

Industry insiders said that the partial revision of the \”Building Design Fire Protection Code\” and the adjustment of illustrations will bring Project design, construction, acceptance and other issues should be treated differently to prevent and control risks.

For projects that have not yet started, especially projects with a reserved door opening width of 1 meter

It is recommended that the design unit recalculate the width of the reserved opening, or remind the entrance door manufacturer in the future On the premise of ensuring quality, pay attention to the size of the door frame and ensure the net width of the entrance door; for the main construction phase of the project, if the reserved door opening width is 1.0 meters, it is recommended that the design institute review whether the reserved opening can be expanded, or adopt a method that meets the requirements Clear width requirements for entry doors.

For a completed project, if the measured width of the entrance door is less than 0.9 meters, it is recommended to conduct a detailed analysis of specific problems based on the measured width on site

The width error of the entrance door should be within 5% ( Net width is greater than 0.855 meters and less than 0.9 meters): According to Article 20 of the Ministry of Housing and Urban-Rural Development’s \”Regulations on Fire Protection Design Review and Acceptance of Construction Projects\”, the error does not exceed 5%, and it can be determined without affecting normal use functions and fire safety. To be qualified.

The net width of the entrance door is greater than or equal to 0.8 meters and less than 0.855 meters:

You can check the time when the \”Construction Engineering Fire Design Review Opinion\” was passed. If it was in 2018 Approval must be passed before November 1, 2019 (Illustration of \”Code for Fire Protection Design of Buildings\”, Atlas No. 18J811-1, date of approval), According to Article 40 of Order No. 51 of the Ministry of Housing and Urban-Rural Development, \”Before the implementation of the newly promulgated national fire protection technical standards for engineering construction, if the fire protection design of the construction project has been reviewed and qualified in accordance with the law, it shall be implemented according to the standards of the original review opinion\”, and it will be determined to be qualified; otherwise, it will be determined to be qualified. It is unqualified (note: 0.8 meters is based on the latest partial revision of the \”Building Design Fire Protection Code\”).

The net width of the entrance door is less than 0.8 meters:

It is judged as unqualified and the entrance door needs to be replaced.

Of course, the judgment of the above-mentioned qualified conclusion when it is less than 0.9 meters should be made by the construction unit to review the project design review time and the standards and specifications adopted.

Industry insiders said that as fire protection acceptance inspection becomes more and more strict, such conflicts accumulated in the early stage will gradually be resolved.

本站内容及图片来自网络,版权归原作者所有,内容仅供读者参考,不承担相关法律责任,如有侵犯请联系我们:609448834

(0)
华夏门网's avatar华夏门网
上一篇 2025年1月11日 10:28:58
下一篇 2025年1月11日 10:31:58

相关推荐

  • 装修日记18(安门大吉) 百分之99的人都选择这样的入户门

    百分之99的人都选择这样的入户门。 正在装修或者准备装修的朋友们看过来,看下我家的安门过程。今天是个好日子,师傅们早早就在做准备工作。安门的师傅只有一人,我问师傅一个人就够吗?师傅说你看我行不行?我跟师傅说还是来帮你扶下。 没一会儿师傅就把门景和门框拼装好,接着就装到门洞上,中途休息师傅擦擦汗。擦完汗后师傅接着继续调整门框水平,泥工师傅也加入战场把缝隙补上。…

    入户门 2024年6月16日
    400
  • 入户门怎么选?除了颜色你更应该考虑的是这个

    欢迎点击主页,关注我们立邦刷新服务,了解更多装修改造知识! 很多业主都会问到关于“防盗门”的问题,然而,选好一扇入户门,需要考虑的可不仅仅是拒绝“猪肝色”的问题,更需要考虑它的安全性能、防盗性能和隔音性能等因素。因为,可不是所有的入户门都具有防盗性能,一扇合格的入户门可是有不少门槛的要求。 入户门选择:先看安全等级 记得以前的老公房,房门基本是木门,为了提高…

    入户门 2024年2月4日
    480
  • 新房装修,开发商装的入户门,要不要换?什么时候换?看完不纠结

    装修中第一个踩的坑,大多数都会出现在开发商给的入户门。新房交楼,很多新手在纠结,开发商安装的入户门是否要更换。入户门是家的门面,讲究大方得体,不换吧,担心开发商送的入户门不安全,标配的猪肝色颜值样式不美观。换吧,又要多花一笔钱。 今天就和大家聊聊,新房装修,开发商送的入户防盗门,到底要不要更换?什么时候更换,更换时要注意什么? 一,看钢印防盗等级。 根据门的…

    入户门 2023年9月27日
    190
  • 年度盘点2023最值得买的入户门

    最近还在装修准备换入户门的家人们抓紧啦,快过年了工厂就要放假了,还在纠结买什么款式?今天给大家盘点一下2023最值得买的入户门,总有一款适合你! 1.性价比超级高款! c1038玉宇:2000+就能买到甲级防盗门,性价比之选了~ 而且极简设计也非常的大气,经典不易过时,质量也很“抗打”锌合金打造、实心密封条,加装防撬槽超安全~ 2.轻奢高级款! C1078W…

    入户门 2023年12月29日
    3270
  • How to choose doors and locks for decoration? Ten years of designers share 6 entry door experiences to avoid many detours

    As the weather turns cooler, the peak home decoration period is here again, and many friends have begun to start interior decoration. When everyone is keen on choosing wall color, …

    入户门 2024年12月12日
    90

联系我们

400-800-8888

在线咨询: QQ交谈

邮件:[email protected]

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信