Medical lead doors and airtight doors for radiology departments

Medical lead doors and airtight doors for radiology departmentsShengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/

Radiation-proof barium sulfate construction

How does barium sulfate protect against radiation

Barium sulfate, also called barite, has been widely used in health centers, mainly to prevent radiation damage to limbs. The rule is that barium sulfate possesses mechanical properties that absorb X-rays.

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/

CT room The percentage and construction method of radiation-proof barium sulfate

Barium sand: Shimin soil = 4:1, apply in batches, apply 1 cm each time, four times It\’s done, enough to solidify and reinforce the net inside.

What is the percentage of barium sulfate:cement block:sand in the anti-corrosion wall of the X-ray room?

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn / Barium sulfate sand and aerated cement are mixed at a ratio of 4:1 (4 parts barium sulfate + 1 part cement block) and are drawn on the wall or floor. The thickness is thin and the wall is lifelike. It only needs 15mm. Yes, the floor is 20mm. It is also sufficient to use lead plate for protection (1-2mm thickness is enough). Lead sliding door: the lead equivalent is 3 equivalents. Observation window: wired glass thickness is up to 15mm.

CT room, visiting room—the wall is notA lead plate (thinnest 3mm) must be used as a radiation barrier, and the floor can be coated with 40mm of barium sulfate + aerated cement in a ratio of 4:1. Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/ Lead School Gate: The chemical equivalent of lead must reach 4-5 equivalents. Observation window: The thickness of lead glass must be up to 20mm.

The original prevention of X-ray machines: the original appearance and health of X-ray machines are the most important part of X-ray prevention. The bulb cover and shield should not leak radiation, and the window should be equipped with an aluminum filter plate. The air radiation rate where the wire harness enters the patient\’s skin should not exceed 6R/min. Especially when using a bed tube for fluoroscopy, if the X-ray tube and its accessories have radiation leaking out, the staff and patients will be exposed to first-hand radiation.

Efforts should be made to shorten the radiation time of X-rays. Before getting involved in surgery, strict operating procedures should be formulated, relevant information about the diseased patient should be obtained, and the exposure of the snake\’s feet should be minimized. Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/ The total exposure time during the operation should not exceed 30 minutes, and the upper and lower illumination criteria should be optimized to avoid re-radiation.

Adopt to improve the separation between the surgeon and the radiation source (i.e., the tube tube) and the scatterer (i.e., the subject of reflection), reduce the radiation dose received by the surgeon, and deviate from each When the exposure is doubled, the radiation dose decreases by 3/4. During the exposure, the surgeon and key assistants should stay away from the X-ray radiation source.

Install a shield between the radiation source and the worker to reduce or eliminate the radiation exposure. If the shield is equipped with lead clothing, lead apron, lead cap, Lead glasses, lead gloves, etc. Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/

Medical lead doors and airtight doors for radiology departments

Medical lead doors and airtight doors for radiology departments

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/Medical lead doors and airtight doors for radiology departmentsShengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/

Medical lead doors and airtight doors for radiology departments

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/Medical lead doors and airtight doors for radiology departments

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/Medical lead doors and airtight doors for radiology departments

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/

Medical lead doors and airtight doors for radiology departments

Shengdun Medical Technology Co., Ltd. http://www.shengdunmt.cn/

本站内容及图片来自网络,版权归原作者所有,内容仅供读者参考,不承担相关法律责任,如有侵犯请联系我们:609448834

(0)
华夏门网's avatar华夏门网
上一篇 2025年1月2日 10:17:22
下一篇 2025年1月2日 10:20:22

相关推荐

  • 医用气密自动门常见的故障和解决办法

    随着社会的不断发展,人们的生活水平也在不断提高,自动化设备越来越受到人们的 重视,很多医院都开始使用自动门,为病人提供更洁净、更方便的服务。医用气密自动门 就是医院常用的一种自动门,因其高度的密封性能满足一定的医疗卫生要求而广受好评, 但是长期使用,难免也会出现故障,为了帮助大家更好地使用,下面由山东鑫聚得介绍一下医用气密自动门常见的故障和解决办法吧! 医用…

    医用门 2023年9月28日
    290
  • National standards for medical doors

    \”General Technical Requirements for Medical Doors in Buildings\” is a Chinese national standard that will be implemented on February 1, 2023. Chinese name General tech…

    医用门 2024年12月16日
    160
  • Yongsheng Glass Technology improves the steel technology of medical door glass and improves the durability of glass products

    In the construction of medical facilities, medical door glass is an important product material, and its protection and durability are related to the quality of the internal environ…

    医用门 2025年3月2日
    130
  • 永剛玻璃科技根據如今使用場地逐漸提高的需求,創新醫用門玻璃

    在當今社會,隨著行業水平的持續提高和醫用環境的逐漸復雜化,醫用領域其內部設施的設計與創新成瞭保護患者、提高服務質量的重要因素。其中,醫用門玻璃作為醫用場景內部空間分隔區域劃分的重要因素,其性能與設計的革新顯得較為重要。永剛玻璃科技捕捉到瞭這一市場需求的變化,以創新為驅動力,推動醫用門玻璃領域的新變革。隨著醫用技術的進步和患者需求的多樣化,現在對於醫用場景空間…

    医用门 2024年9月9日
    70
  • 病房门的尺寸是多少啊?

    病房门属于工程门一类,都是定制尺寸,不存在固定尺寸。但是设计师也有比较常规使用的尺寸。  国内病房工程门分为单开门、子母门、双开门和单扇平移门,一般使用的尺寸是:  单开门高度为2100mm(加亮窗会增高300-500mm),单开门宽度为900-1000mm。  子母门高度为2100mm(加亮窗会增高300-500mm),子母门宽度为1100-1200mm。…