Part 2

1. Rotork

1. For regulating actuator (IQM type):

4~41 short, 5~39 short Connect

26+, 27-Analog signal instructions

22 +, 23-valve position feedback signal

2. As a switch type electric valve (IQ type)

4~36 short circuit

5~34 short circuit (no short circuit when there is a stop command)

Command: On: 35, 5 Off: 33, 5

Feedback: On: Level 8, 9: 6, 7

Analog current feedback: 22+, 23—

Power failure feedback: 42, 43 (normally closed)

The instructions for imported electric doors are the same, and the feedback is: 15 16

2. Autork

1. Adjustable actuator (IKM type):

4~36 short circuit 5~39 short circuit

Analog signal instructions: 26+, 27—:

Valve position feedback signal: 22+, 23—

2. For switch type electric valve (IK type)

4~36 short circuit

5~34 short circuit (if there is a stop command, stop in the middle and do not short circuit)

Commands: On: 35, 5 Off: 33, 5

Stop: 34, 5

Feedback: On: 8, 9 Off: 6, 7

SimulationAmount of current feedback: 22+, 23—

Power failure feedback: 42, 43 (normally closed)

3. Auma

1. Use as a regulating electric valve

Commands: 2+, 3— Feedback: 24+, 23—

2. Use as a switch type electric valve

Command: On: 3, 11 Off: 2, 11, Stop: 11 4

Feedback: On: 39, 40 Off: 35, 36

4. Yangzhou Siemens Integration Electric door

1. LK series

(1), as a regulating electric valve

Analog instructions: 15+, 16-

Analog feedback: 13+, 14-

(2), as a switch type electric valve

Commands: On: 18, 21 Off: 19, 21

Feedback: On: 3, 4 Off: 1, 2

Analog feedback: 13+, 14—;

(3), power supply

AC380V:22(A), 23(B), 24(C);

AC220V:23(L), ​​24(N)

2. WK series (domestic technology)

For on-off electric valves

Commands: On: 3, 4; Off: 2, 4

Stop command 1, 4

Feedback: On: 17, 18; Off: 5, 6

Analog feedback: 8+, 7— Power failure: 9 21

Self-maintaining: If X11 needs to be moved, unplug this plug

5. sipos execution agency

1. ECOTRON economical version: round plug connection with relay board (electric door)

Short circuit: 5, 6 terminals

Commands: On: 3, 1; Off: 2, 1

Emergency off: 9, 10 Stop: 4, 1

Feedback: On: 28, 29; Off: 32, 33

Analog feedback: 7+, 8—

2. PROFITRON Professional:

Round plug-in connection with relay board (adjusting door)

Analog current command: 11+, 12-

Analog feedback: 7+, 8—

3. ECOTRON Economical

Direct connection with relay board (electric door);

Divided into four terminal strips: X3: 1, X3: 2, X1, and X2

Short circuit: terminals 18 and 19 (X3: 2 terminal strip)

Command: Open: 5, 3; (X3: 1 terminal strip)

Off: 4, 3 Stop: 6, 3

Feedback: Open feedback is connected to 1 and 2; (X2 terminal strip)

Close feedback to 5 and 6

Power supply is connected to X1 terminal block L1, L2, L3

4. PROFITRON Professional

Direct connection with relay board (regulating door);

Divided into four terminal strips: X3: 1, X3: 2, X1, and X2

Short circuit: 18, 15 terminals (X3: 2 terminal strip)

Analog instructions: 14+, 15- (X3: 2 terminal strip)

Analog feedback: 1+, 2- (X3:1 terminal strip)

Feedback on: 1, 2 (X2 terminal strip)

Close feedback: 5, 6

Power failure: 17, 18 (normally closed)

6. SCHIEBEL (jog control wiring)

Short circuit: 2~3 terminals (provide power)

Commands: On: 1, 4 Off: 1, 3

Current feedback: 23 (+) 24 (—)

7. ABB tune gate

Command: 34 (+) 33 (—)

Feedback: 35 (—) 36 (+)

Short circuit: 21~15 22~16 (used to provide remote control power supply) 21+ 22—(24V power supply provided internally)

ABB electric door

Commands: On 11 12 Off 13 14

Feedback: On 7 8 Off 9 10

ABB pneumatic door

Command: 11 12 (used to supply power to the control part)

Feedback: 31 32 (requires DCS to provide 24 power supply)

8. ROTORK made in Malaysia (non-integrated)

Power: 1 2 3

Close travel switch (normally open): 8 9

Open travel switch (normally open): 17 18

Current level inverse: 32— 23+

9. QP10POO—02 (ROTORK)

Command: Off 33 34 On 34 35

Feedback: On 15 16 Off 6 7

10. 1614X90—04 (ROTORK) Tune the door

Command: 22+ 13—

Feedback: 32+ 23—

Eleven. 1410—50 ROTOCK (domestically produced in Shanghai)

Gate adjustment commands: 22+ 13—

Feedback: 32+ 23—

Electric door inching

Command: On 39 37 Off 39 38

Feedback: On 15 16 Off 8 9

If self-holding is required, short circuit: 36~39

Power failure: 41 42

Twelve. Hunan Lisheng Information Equipment Co., Ltd.

Shorting: 1~2 1~5

Power: L1 L2 L3

Command: On 2 3 Level: 2 4

Feedback: On 6 8 Off: 7 8

Torque switch: on 11 9 off 11 10

Thirteen. ABB electric pump spoon tube door adjustment

Command: 26+ 27—

Feedback: 30+ 31—

Power supply: 14+ 15—

14. Electric doors produced by Jiangsu Baiyun Electric Machinery Factory

Power: 11 12 13 (Row A)

Commands: 3+ 4—

Feedback: 5+ 6— Far and near control switching: 7 8

(7 8 short-circuit remote control)

(Row B) Feedback: On 1 2 Off 3 4

Fifteen. PS wiring

Feedback: 7+ 8—

Command: 3+ 4—

16. Chongqing Sichuan Yi Electric Door

Power supply; L1 L2 L3 PE ground

24V internal power supply 21+ 22—

Command: Off 21 13 On 21 11

Feedback: Off 9 10 On 7 8

Short circuit: 22 ~ 12 24 ~ 14 (can not short circuit)

Chongqing Sichuan Yi Door Adjustment

Short circuit: 21~15 22~16

Command: 34+ 33—

Bit inversion: 36+ 35—

Seventeen. Changzhou Lanling integrated valve wiring

Command: open 6 8 Off 6 7 Stop 6 9

Feedback: On 5 6 Level 9 10

Short circuit 2 5 for near and far control

1+ 2—used to provide 24V power supply to the control board

18. Electric pump spoon tube wiring

Power supply (110V): 1 2

Emergency command: on 6 7 off 6 8

Current command: 9+ 10—

Feedback: 11+ 12—

Nineteen. Ricky RA series electric door

Command: Off 5 33 On 5 35

Feedback: Off 6 7 On 10 11

Short circuit: 5~34 (for self-maintaining) 4~36

RQ series door adjustment

Feedback: 22+ 23—

Command: 26+ 27—

Twenty.AUMA electric door wiring (non-integrated)

Close travel switch: 9 10 (normally closed) 11 12 (normally open)

Closing torque switch: 1 2 (normally closed)

Open travel switch: 13 14 (normally closed) 15 16 (normally open)

Opening torque switch: 5 6 (normally closed)

21. Tianjin Baili SMC series wiring diagram

Command: On: 34 17 Off: 34 18 Short: 20 35

(Instructions require DC24V power supply, 22+ 23—)

Feedback: On: 24 28 Off: 26 28 Fault: 16 15

(The terminal number is based on the number on the number tube)

22. Shanghai Automation Instrument No.11 Factory 1410-50-CA (wiring diagram)

Command: On 36 37 Off 36 38 Self-maintaining: 36 39

Feedback: On 10 11 Off 8 9 Failure: 41 42

23, JORDAN American Jordan wiring

Power supply: 1 live wire 2 neutral wire Command: 3 (+) 4 (—)

Feedback: 5 (+) 6 (—)

24. Yangzhou Electric Power Equipment Repair Factory Model: 040-0.5WZ Wiring

Current feedback: 4 (+) 5 (—) Command: Off 7 9

On: 8 9 9 (Hold) DC24V: 13+ 14—

25 , German EMG wiring

Electric door: Command: On: 20 3 Off: 20 4 Stop; 20 2 Short: 21 1

Feedback: Off: 5 7 On; 5 9

Failure: 5 10

Tiaomen: Command: 22+ 24— Feedback; 23+ 24—

26. Yangzhou Electric Power Equipment Factory Model: LU—10—1

Terminals: 1 2 3 (resistor)

11 5 Open stroke torque normally closed contact

11 6 Close stroke torque normally closed contact

11 8 Open stroke torque normally open contact

11 9 Close stroke torque normally open contact

7 torque normally open common point

D1 D2 D3 Motor power supply 380V

Note: For reference only, the actual instructions shall prevail.

Part 3

1 RAGA electric door terminal block:

Open command: 5 –35

Close command: 5–33

Open feedback: 6–7

Close feedback: 10–11

Fault: 42 –43

4-36, 5-34 short circuit

2 ABB electric door terminal block:

Open command: 21 –11

Close command: 23–13

Feedback on: 7–8

Feedback off: 9 –10

Fault: 4 –5

22—12, 24—14 short circuit

3 British ROTORK electric door terminal block:

Open command: 5 –35

Close command: 5–33

Open feedback: 15–16

Close feedback: 6 –7

Fault: 24 –41

4–36 , 5-34 short circuit

4 EMG two-position electric door terminal block:

Open command: 4 –20

Off Command: 3–20

Enable feedback: 5–9

Related feedback: 5 –7

Fault: 5 –10

1–21 short circuit

5 EMG adjustable electric door terminal block:

Command: 22 –24

Feedback: 23….24

Close feedback: 5…7

Open feedback: 5…9

Fault: 5 –10

1–21 2…20 short circuit

6 Jordan adjustable electric door terminal blocks:

Commands: 3…4

Feedback: 5…6

Power: 1…2

7 AUTORK (IKM) Electric door terminal block:

Commands: 26 –27

Feedback: 22—23

Open feedback: 6—7

Close feedback: 8—9

5-39, 4-41 short circuit

8 AUTORK (IK) electric door terminal block:

Open command: 5–35

Guanzhifeed: 5—33

Feedback on: 8—9

Feedback off: 6–7

Fault: 42 –43

4-43 short circuit

9 AUTORK (IQ) electric door terminal block:

Open command: 5–35

Close command: 5—33

Open feedback: 8—9

Close feedback: 6–7

Fault: 42 –43

4—36 5—34 short circuit

10 AUTORK adjustable type

Instructions: 26 –27

Feedback: 22—23

Feedback: 6—7

Open feedback: 8—9

Fault: 4 –5

5-39, 4-41 short circuit

11 RAGA adjustable type

Command: 26 –27

Feedback: 22—23

Feedback: 6—7

Open feedback: 10–11

Fault: 4 2 –43

5—39, 4—41 short Continue

12 Shangyi Tiaomen Adjustable Type

Command: 26 –27

Feedback: 22—23

Feedback: 6—7

Open feedback: 8—9

Fault: 4 2 –43

5-39, 4-41 short circuit

13 AUMA two-position electric door terminal block:

Open command: 3 –11

Close command: 2–11

Feedback on: 39–40

Feedback off: 35 –36

Fault: 14 –15

Yangxiu valve two-position electric slow door opening:

Reference: On, 3, 4

Off, 2, 4

Feedback: On, 17, 18

Off, 5, 6

Failure, 9, 21

Far away, 10, 11: self-maintained, 19, 20:

Power supply: 220VAC, 24L, 12N

Ecott:

Refer to today: open, 3, 1

Off, 4, 1

Feedback: On , 8, 9

Off, 6, 7

Failure, 12, 13

14.15 Valve position

Far away, 10, 11: Self-maintained, 19, 20:

Part 4

1.ROTORK

1 , as an adjustable actuator (IQM type)

4-41 short circuit 5,39 short circuit

26, 27, Analog signal instructions

22, 23, valve position feedback signal

2. For switch type electric valve (IQ type)

4,36 short circuit 5,34 short circuit (if there is a stop command, do not short circuit during the stop)

Command: On: 35, 5 Off: 33, 5

Feedback: On: 8, 9 Off: 6, 7

Analog current feedback: 22, 23 ,

Power failure feedback: 42, 43 (normally closed)

二Autork

1 for regulating actuator (IKM type):

,36 short circuit 5, 39 short circuit 4

Analog signal instructions: 26, 27,

Valve position feedback signal: 22, 23,

2 switch type electric valve (IK type)

4,36 short circuit 5,34 short circuit (stop in the middle if there is a stop command) No short circuit)

Command: On: 35, 5 Off: 33, 5 Stop: 34, 5

Feedback: On: 8, 9 Off: 6, 7

Analog current feedback: 22, 23,

Power failure feedback: 42, 43 (normally closed)

3. Auma

1 for regulating electric valve

Instruction: 2,, 3, feedback: 24,, 23, 2 for on-off electric valve

Commands: On: 3, 11 Off: 2, 11 Stop: 11, 4

Feedback: On: 39, 40 Off: 35, 36

4. Yangzhou Siemens integrated electric door

1. LK series

1), as a regulating electric valve

Analog instructions: 15,, 16,

Analog feedback: 13,, 14,

2) As a switch type electric valve:

Command: On: 18, 21 Off: 19, 21

Feedback: On: 3, 4 Off: 1, 2

Analog feedback: 13, 14 ,

3) Power supply

AC380V:22(A), 23(B), 24(C)

1/4 page

AC220V:23(L), ​​24(L)

2.MK series (domestic technology)

For switch type electric valve;

19,20 short circuit

Commands: On: 3, 4 Off: 2, 4 Stop: 1, 4

Feedback: On: 17, 18 Off: 5, 6

Analog feedback: 8, 7, power failure: 9, 21

Self-maintaining: If X11 needs to be moved, unplug this plug

5. Sipos actuator

1. ECOTRON economical type: round plug-type connection with relay board(Electric door) Short circuit: 5, 6 terminals

Command: Open: 3, 1 Close: 2, 1 Emergency close: 9, 10 Stop: 4, 1 Feedback: Open: 28, 29 Off: 32, 33 Analog feedback: 7, 8,

2. PROFITRON professional type: circular plug-type connection with relay board (adjusting door)

Analog current command: 11, 12,,, 8, Analog feedback: 7

3. ECOTRON economical type: direct connection with relay board (electric door)

Divided into four terminal strips: X3:1, X3:2, X1, and X2

p>

Terminals 18 and 19 (X3: 2 terminal strip) short circuit:

Command: On: 5, 3 Off :4, 3 Stop: 6, 3 (X3:1 terminal strip)

Feedback: On: 1, 2 Off: 5, 6 (X2 terminal strip)

The power supply is connected to X1 terminal block L1, L2, L3

4. PROFITRON Professional: direct connection with relay board (adjusting door)

Divided into four terminal blocks: X3:1, X3:2, X1, and X2

Short-circuit: 18, 15 terminals ( X3: 2 terminal strip)

Analog instructions: 14, 15, (X3: 2 terminal strip)

Analog feedback: 1,, 2, (X3: 1 terminal strip)

p>

Open feedback: 1, 2 (X2 endsub-row)

Close feedback: 5, 6

Power failure: 17, 18 (normally closed)

Six (SCHIEBEL (jog control wiring)

Short circuit: terminals 2 and 3 (provide power)

Command: On: 1, 4 Off: 1, 3

Current feedback: 23,, 24,

Seven (ABB Adjustment Gate

Command: 34,, 33,

Feedback: 35,, 36,

Short-circuit: 21,15, 22,16 (used to provide Remote control power supply)

21,, 22, (24v power supply provided internally)

ABB electric door

Command: open 11, 12, close 13, 14

Page 2/4

Feedback: On 7, 8, Off 9, 10

ABB pneumatic door

Instructions: 11, 12 (used to supply power to the control part)

Feedback: 31, 32 (requires DCS to provide 24v power supply)

Eight (Malaysian ROTORK (not one-piece) )

Power: 1, 2, 3

Close travel switch (normally open): 8, 9

Open travel switch (normally open): 17, 18

Current bit inversion: 32, 23,

Nine(QP10POO,02(ROTORK)

Command: Off 33, 34, On 34, 35

Feedback: On 15, 16, Off 6, 7

Ten (1614X90-04(ROTORK) door adjustment

,, 13, command: 22

Feedback: 32,, 23,

November, 1410,50 RORORK (Made in Shanghai)

Gate adjustment instructions: 22+, 13,

Feedback: 32,, 23,

Electric door jog

Command: open 39, 37, close 39, 38

Feedback: On 15, 16, Off 8, 9

If self-holding is required, short-circuit: 36,39

Power failure: 41, 42

Twelve, Hunan Lisheng Information Equipment Co., Ltd.

Short: 1,2, 1,5

Power supply: L1 L2 L3

Command: On 2, 3 Off 2, 4

Feedback: On 6, 8, Off 7, 8

Torque switch: on 11, 9, off 11, 10

Thirteen, ABB electric pump spoon tube door adjustment

Instructions: 26,, 27,

Feedback: 30,, 31,

Power: 14,, 15,

Fourteen, electric door produced by Jiangsu Baiyun Electric Machinery Factory

Power supply: 11, 12, 13 (row A)

Command: 3,, 4,

Feedback: 5,, 6, far and near control switching: 7, 8 (7, 8 short for remote control)

Page 3/4

B row feedback: On 1, 2, Off 3, 4

Fifteen, PS wiring

Feedback: 7,, 8,

Instructions: 3,, 4,

Sixteen, Chongqing Sichuan Electric Electric Door

Power supply: L1 L2 L3 PE ground

24V internal power supply: 21,, 22,

Command: Off 21, 13, On 21, 11

Feedback: Off 9, 10, On 7, 8

Short-circuit: 22, 12, 24, 14 (can it not be short-circuited)

Chongqing Sichuan Yi Adjusting Door

Short connections: 21,15, 22 ,16

Command: 34,, 33,

Bit inversion: 36,, 35,

Seventeen, Changzhou Lanling integrated valve wiring

Command: open 6, 8, close 6, 7, stop 6, 9

Feedback: Open 5, 6 Off 9, 10

2,5 is used for near and far control short circuit:

1, 2, used to provide 24V power supply for the control board

Eighteen, electric pump spoon tube wiring

Power supply (110V): 1, 2

Emergency command: open 6, 7, close 6, 8

Current command: 9,, 10,

p>

Feedback: 11, , 12,

Nineteen, Ruiji RA series electric door

Command: off 5, 33, on 5, 35

Feedback: Off 6, 7, On 10, 11

Short: 5,34 (for self-holding) 4,36

RO series

Feedback: 22,, 23,

Instructions: 26,, 27,

Twenty, AUMA electric door wiring (non-integrated)

Close travel switch: 9, 10 (normally closed) 11, 12 (normally open)

Close torque switch: 1, 2

Open travel switch: 13, 14( Normally closed) 15, 16 (normally open)

Open torque switch: 5, 6 (normally closed)

(for production examination only, subject to the book of the executing agency)

Disclaimer: The content published on this platform is marked as original. . Reposted and shared contentThe content is for learning purposes only and is for reference only and does not represent my own views and positions. If there is any infringement, please contact us to delete it. Welcome all colleagues to communicate and learn together!

本站内容及图片来自网络,版权归原作者所有,内容仅供读者参考,不承担相关法律责任,如有侵犯请联系我们:609448834

(0)
华夏门网's avatar华夏门网
上一篇 2024年12月25日 10:25:31
下一篇 2024年12月25日 10:28:24

相关推荐

  • So convenient! The Mengtian experimental cabin is equipped with an \”electric door\”

    Beijing Daily Client | Reporter Liu Suya Correspondent Yang Jing Wang Tianming Chen Yuan On October 31, the launch mission of the Mengtian experimental module was a complete succes…

    电动门 2024年12月26日
    30
  • How much does an electric door cost? Choose a safe door

    Electric doors, also known as \”electric telescopic doors\” or \”electric folding doors\”, are safe and convenient. The application range of modern electric…

    电动门 2025年1月5日
    100
  • 电动伸缩门不锈钢电动门

    电动伸缩门是一种现代化的不锈钢电动门,它具有伸缩灵活、耐用牢固等特点,被广泛应用于商业建筑、工业厂房、大型停车场等场所。本文将从多个角度介绍电动伸缩门的特点和优势。 首先,电动伸缩门的外观设计时尚美观。不锈钢作为主要材质,具有金属光泽和简洁大气的特点,能够与各类建筑风格相匹配。通过专业设计师的巧妙设计,电动伸缩门外观线条流畅、造型独特,给人一种现代、时尚的感…

    电动门 2023年10月1日
    280
  • ……….

    想不想吃一道简单又美味的家常菜?那就快来学习一下这款让人垂涎欲滴的番茄炒蛋! ·首先需要准备新鲜的鸡蛋和番茄,将番茄洗净切块,鸡蛋打散备用。为了保证口感,建议大家用筷子或打蛋器将鸡蛋打散,搅打至均匀稠密。 ·接下来可以开始炒蛋了,在热锅里加入适量的食用油,用中小火将油温加热至六成热,然后将鸡蛋液倒入锅中,用筷子或铲子迅速搅拌,等到鸡蛋熟透后,用铲子将它捞出放…

    电动门 2024年3月8日
    540
  • 电动门推拉门

    电动门推拉门是一种现代化的门禁系统,可以为用户提供更加便捷、安全的进出通道。它的广泛应用于商业建筑、机场、地铁站、酒店等场所,为大家的生活带来了极大的便利。本文将从不同的角度来介绍电动门推拉门的优势和应用场景。 首先,电动门推拉门在用户使用方面具有显著的优势。传统的门开关方式需要用户手动推拉,而电动门推拉门则通过电动驱动,使门的开关更加轻松、便捷。无论是长时…

    电动门 2023年10月17日
    80

联系我们

400-800-8888

在线咨询: QQ交谈

邮件:[email protected]

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信