National standards for medical doors

\”General Technical Requirements for Medical Doors in Buildings\” is a Chinese national standard that will be implemented on February 1, 2023.

Chinese name General technical requirements for medical doors of building Standard category Basic standard number GB/T 41659-2022

National standards for medical doors

1. Technical specifications for steel medical doors in national standards for steel medical doors

1.1 The production, installation and acceptance of steel doors must meet the latest national standards, specifications and requirements. All materials used in the production and processing of goods are required to be environmentally friendly products.

1.2 All kinds of doors must be equipped with all accessories, including door leaf body, door frame, filling, locks, hinges, hidden latches, glass (glass depends on the functional needs of the room), etc. .

1.3 The color of the goods is made according to environmental requirements.

1.4 Medical door products must have test reports from relevant national departments.

2. Material selection and production requirements

2.1 Medical door frame

1. The material of the medical door frame is Shougang or Baosteel\’s high-quality flower-free and oil-free hot-dip galvanized steel plate. The thickness of the bare steel plate is ≥1.5mm. The steel must be Baosteel or Shougang\’s domestic high-quality steel.

2. The medical door frame is assembled on site to ensure the integrity and solidity of the door frame and wall.

3. The medical door facade adopts the form of double-sided full cover (set A + set B) to ensure the integrated design and aesthetics of the door frame and wall. importThe equipment is integrally bent and formed, with 90° diagonal connection technology, German European style folding design, and must have an \”R-shaped\” groove design, with high-quality rubber sealing strips embedded inside, making it easy to disassemble and clean.

2.2. Medical door leaf

1. Medical door leaf material: The steel must be domestically produced by Baosteel or Shougang. High-quality double-sided hot-dip galvanized flower-free and oil-free steel plate. The thickness of the bare steel plate is ≥0.8mm. The lining at the bottom of the door leaf is made of ≥0.8mm galvanized steel reinforcement plate to ensure its firmness and stability.

2. The thickness of the medical door leaf is 40mm. Each surface of the door panel is flat and smooth, with no solder joints. The door leaf is formed by one-time bending using a professional flexible bending center. There are no seams or joints on the surface. The side of the door leaf has single-seam locking links and no solder joints on the side. In order to fully consider the door leaf. There must be no exposed rivets, screw holes, welding spots, or welds around the door panel.

3. The interior of the medical door is filled with high-strength, high-density, high-strength, high-density honeycomb paper from the Dutch imported brand \”Hollisheng\” as the door panel filling material. The diameter of the honeycomb paperboard hole is 15㎜. It is fully bonded to the steel plate to ensure its stability and high-strength impact resistance.

4. According to the room function, the bathroom door panel is equipped with \”herringbone\” nylon ventilation louvers, and the ward door is equipped with aluminum alloy glass with a surface spliced ​​at 90 degrees or 45 degrees. Window, the window glass is 6mm tempered glass. The bathroom blinds are in nylon original color, and the window color is the same as the door body color.

3. Locks, hinges, top and bottom pins, seals

3.1. Medical door handles and panels are made of imported materials Branded stainless steel handle, quality guaranteed to be opened no less than 500,000 times. The bathroom door lock cylinder requires a \”one\” shape design to ensure the safety of its use and the smoothness of opening the door. The hardware must be American Stanley, German Duoma, and German ECO.

3.2. Medical door hinges: Use 304 stainless steel butterfly hinges and locks of the same brand. Door frames and door leaves must use steel reinforcing plates as reinforcements, and stainless steel machines are used to fix the hinges. The screws and hinges must be reinforced with threaded holes before leaving the factory (it is strictly prohibited to use wooden materials as reinforcements), which can fully ensure their firmness and stability, and will not occur when the door leaf is opened frequently for a long time. Sagging phenomenon.

3.3. Medical door top and bottom pins and center seam cover. The ward door adopts the form of double and double fans. The top and bottom pins of the sub-fans are split type top and bottom pins made of 304 stainless steel. The center seam cover of double-fold doors or double doors needs to be double-sided to ensure the overall airtightness and appearance of the door leaf.Spend.

3.4. Standards for matching lock cylinders for medical doors:

(1) Double-sided lock cylinders are used for ward doors to prevent The patient locked the door, causing inconvenience, and each floor is provided with a set of keys as standard.

(2) The bathroom door uses a \”one\” shaped bathroom single-sided lock cylinder, which can fully consider that in the event of an emergency, the patient is outside the door and does not use any special tools. , the door can be easily opened with just a coin.

(3) The use of a single-sided handwheel lock cylinder for the outpatient office door can fully consider the privacy and convenience of doctors and patients during treatment.

(4) Sealing strip: The door frame has an \”R\”-shaped groove, and a removable pure natural rubber sealing strip is embedded in the groove. The door frame and rubber sealing strip are connected non-adhesively. The sealing strip is removable and cleanable to meet the requirements of a hygienic environment.

4. Medical door panel color

4.1. The surface of the medical door frame and door panel is treated with electrostatic powder spraying , requiring high strength wear resistance, corrosion resistance and impact resistance. The spraying should be even and there should be no paint leakage or touch-up. The powder is required to be imported brands, and the environmental protection requirements must meet or exceed the national standard level. The powder is required to be imported from the Austrian “Tiger” brand or the Dutch “Aksu” brand. The surface spraying process is electrostatic fluid spraying. The coating is uniform, flat and smooth, without pitting, bubbles, paint leakage or paint peeling. The spraying layer is uniform, not less than 65 microns. The surface spraying is uniform and has strong adhesion. The surface effect is color Lifelike, easy to clean, and relatively resistant to bacteria and corrosion.

4.2. Medical door color: The specific color shall be based on the color of the steel door in the first phase or selected by Party A based on the national standard RAL color card sample.

5. Medical door glass, windows, blinds and installation requirements

5. 1. Ward doors are made of aluminum alloy The material surface is a glass window spliced ​​at an angle of 90°. The window glass is 6 mm tempered glass.

5.2. Medical door window:

①Aluminum alloy glass frame is used with rubber glass strips, and national standard tempering is selected The surface of the glass and glass frame is spray-painted in the same color as the door leaf to achieve a unified and coordinated style.

② The window frame adopts the same 450 or 900 connection as the door frame to avoid gaps in the corners. There are no screw holes on the surface, which is easy to clean and ensures the integrity and integrity of its angle with the door frame. Coordination.

5.3. HygieneRoom ventilation louvers

are made of nylon and adopt the most advanced foreign double-layer \”herringbone\” shaped ventilation louvers, which can fully ensure its ventilation function and patient privacy. To ensure its beauty and integrity.

2. Medical door installation process:

① The door frame and door leaf of the medical door are installed separately on site to facilitate transportation Simple and convenient for finished product protection. The door frame adopts the vertical and horizontal frame assembly and disassembly style, and is installed with built-in screws. Easy to assemble, low error, allowable deviation of door frame inner width is ±1mm, verticality of two frames ≤2mm, door frame diagonal difference ≤3mm, door frame reference line elevation <2mm, door frame installation position in the opening <5mm, door leaf Install after grouting is complete. There is no interface in the middle when the door frame sealing strip is installed. The door leaf and door frame are assembled with high precision to ensure the sound insulation performance of the door body.

② Medical door hinges are made of 304 stainless steel, with strong load-bearing capacity and stable performance. The hinge must be installed with a hinge lining plate of more than 1.5mm, and it is forbidden to make separate holes in the door frame and door leaf.

本站内容及图片来自网络,版权归原作者所有,内容仅供读者参考,不承担相关法律责任,如有侵犯请联系我们:609448834

(0)
华夏门网's avatar华夏门网
上一篇 2024年12月16日 10:41:15
下一篇 2024年12月16日 10:44:15

相关推荐

  • 新冠11类疑似症状门急诊费用如何报销?北京医保发布政策

    导 读 1月8日,北京市医保局发布消息,本市参保患者在本市二级及以下定点医疗机构发生的新冠病毒感染及11类疑似症状的相关的门急诊费用,不设起付线和封顶线,报销比例为90%。 市医保局表示,根据《国家医保局财政部国家卫生健康委国家疾控局关于实施“乙类乙管”后优化新型冠状病毒感染患者治疗费用医疗保障相关政策的通知》,本市对医疗保障相关政策进行了优化调整。新型冠状…

    医用门 2023年10月23日
    130
  • 医院病房卫生间门有哪些区别?

    Q1:医院卫生间门的要求 1、当在选择病房医用门的时候,需要考虑一下周围环境针对病房医用门带来的影响。 2、医院气密门门体设计采用经表面喷塑的大平面不锈钢板材、铝塑板、PVC钢板例如防火板,放有密封条,符合医院使用的卫生要求,门体可有十多个颜色选择。 3、立即将病房医用门做成怎么样的又合理,合理即合适便美观,仍然能达到使用要求,因此与户外的某些物品能够和谐相…

    医用门 2023年12月6日
    470
  • Yonggang Glass Technology introduces new glass tempering equipment to improve the impact resistance of medical door glass

    With the development of the medical industry, every subtle improvement is related to the protection and comfort of patients. Medical doors are an indispensable part of the medical …

    医用门 2025年1月6日
    20
  • 医用钢制洁净自动门的功能特点有哪些?

    医院是一个特殊的地方,医院有很多的病人行动不便,所以医院的门一般来说都是自动的,这样腿脚不便的人在进出的时候会方便很多。那医用自动门除了使用方便进行行人,医用钢制洁净自动门的特点有哪些? 1、采用直流无刷电机,体积小,功率大,噪音低,寿命长。 2、配备高传动效率的精密齿轮减速系统,具有运转平稳、扭矩大、控制精度高等优点。 3、优良的程序设计使微处理技术更显特…

    医用门 2023年9月22日
    160
  • 关于医院病房专用门制作及使用特性的几点看法

    病房几乎每天都有轮椅、担架车、送药车出入,难免磕、碰、划木门及门框。工程投入使用不长时间,门和门套便出现不同程度损坏现象。时间越长,损坏的越严重。出现了我们常说的新楼破门现象。由于病房门使用的特殊性,在设计、制作过程中应大程度满足其使用特性。我们的看法是; 一、 铝合金封边 所有门、门套、门口线周边都采用铝合金型材封边。与传统油漆门封边、pvc封边相比,它的…

    医用门 2024年2月9日
    230

联系我们

400-800-8888

在线咨询: QQ交谈

邮件:[email protected]

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信